Shortlist the Hirschmann EAGLE40-4F-ROUTER for a hot wired control cabinet that needs router redundancy. Choose the Teltonika RUT956 if a remote site needs an LTE uplink. EAGLE40 specifications · RUT956 LTE details
Shortlist by use case
| Use case | Exact model | VPN, firewall and port layout | Documentation |
|---|---|---|---|
| Hot wired cabinet with router redundancy | Hirschmann EAGLE40-4F-ROUTER (942333001) | Multipoint VPN with IPsec, stateful inspection firewall, four Gigabit RJ45 ports and Virtual Router Redundancy Protocol (VRRP). | Belden product, security and redundancy specifications |
| Remote cabinet with cellular WAN | Teltonika RUT956 | LTE Cat 4, dual SIM, IPsec and zone-based firewall rules. Choose another model if the cabinet requires Gigabit Ethernet ports. The RUT956 supports 10/100 Mbps wired links. | LTE · Ports · VPN · Firewall |
Check the VPN peer and access rules
- Write down the peer requirements. Record the remote gateway address, Internet Key Exchange (IKE) version, authentication method, local and remote subnets, and the proposals used by both endpoints. Check those requirements against the exact model before ordering. IPsec parameters
- Count tunnels at the appliance that terminates them. List the remote peers and mark which tunnels must be active at the same time.
- Limit vendor access. List each allowed source zone, destination zone, protocol and port for vendor traffic to the control network. RUT956 firewall rules
Check cabinet fit before ordering
Compare the highest and lowest expected temperatures at the mounting location with the operating range below. Check the DC supply against the input specification. Start the rail layout with the housing dimensions and check the space around the mounted unit with cables and any antennas attached. RUT956 mounting drawings
| Model | Housing (W × H × D) | DC supply | Ambient operating temperature |
|---|---|---|---|
| EAGLE40-4F-ROUTER | 48 × 137 × 105 mm, 35 mm DIN rail | Dual 12 to 24 V DC operating voltage | −40 to +70 °C. Belden power and ambient specifications |
| RUT956 | About 110 × 50 × 100 mm, DIN-rail mounting on either side | 9 to 30 V DC at the power socket | −40 to 75 °C. Housing and temperature · Power socket |
Suppose a wired cabinet has a 24 V DC supply, needs VRRP and operates just below 70 °C. The example voltage and temperature fall within the published EAGLE40-4F-ROUTER ranges. Belden lists VRRP for this model. Use its 48 mm housing width to start the rail layout. EAGLE40 specifications
Evidence and limits. Specifications were checked on November 26, 2026 against Belden’s EAGLE40-4F-ROUTER specifications (revision 0.88) and Teltonika’s RUT956 documentation. This guide is not based on hands-on testing.